In the older form, electric heating elements are sandwiched between a layer of drywall and a layer of plaster. Radiant ceiling heat is a style of heating that is significantly different from the radiators or forced air ducts that you may be used to. Have a pro check your ceiling before installing radiant heat. I used radex a form of electric drywall heat 20 plus years ago. My experience would make me shy away from any radiant heat withinbehind drywalled surfacesa few years back i was working on a remodel house age less than 10 years where the ho wanted cracks in the ceiling dw repaired. It seems that once everything has dried out and is stable that the cracks could be repaired and should be fine. How can we disconnect safely so we can install can lighting in the ceiling. The clue is line voltage thermostats on the wall, but no baseboard heaters. Depending on the size of the ceiling i would remove all the plaster, insulate the ceiling and hang new board. It is installed directly to the ceiling framing in much the same way as traditional drywall. Documented by the department of energy and the national association of homebuilders, enerjoy i electric radiant heat panels save 3050% over oil, gas or other electric systems. Before i moved in, i hired a contractor off angies list to install drywall as the concrete ceiling was visually unappealing.
Again, radiant heating is not intended to specifically raise the air temperature like a normal furnace. Radiant ceiling heat drywall falling again contractor talk. With radiant ceiling heat that can be a big difference. Ceiling repair radiant heat in ceiling jlconline forums. May 04, 2009 i have radiant ceiling heat in drywall which was installed in 1968. Drywall replacement on radiant heated ceiling drywall doityourself. They still use the heat, last time they where repaired it was done with mesh tape and spackle compound which did not hold up and i have tried repairing with elastopatch dap product which isnt working as well as i hoped. A direct transference of clean even heat from object to object without fans, pumps or hoses silent, motionless, and invisible. Oct 24, 2011 i have radiant heat in my plaster ceiling and over the past 23 months of digging, major on going excavation, building destruction and construction four feet from my property line the ceilings have cracked in a number of rooms. I have radiant heat in my plaster ceiling and over the past. I taped and repaired the cracks, retextured and left it looking pretty good. Four months have passed and now hairline cracks are. The metal lathe will expand and contract with the heating cooling cycle.
I have radiant ceiling heat in drywall which was installed. The hardware of this device is mounted over the head making it very practical for homeowner living in small houses. Ceiling heat removal demo cleanup how to diy youtube. In fact, there is typically more hot air rising with a radiant floor than with a radiant ceiling. If im going to repair ceilings that cracked from the radiant ceiling heat, the first thing i ask is if they stopped using the ceiling heat. In most cases they cost less than half of a radiant floor. I owned a condo a few years ago with radiant ceiling heat, similar construction timeframe i guess warm air fell in the 70s. When these wires burn out, it is very difficult to repair the system without tearing out most of the ceiling. I have radiant ceiling heat in drywall which was installed in. On top of that, the building was built in the 60s and from what i read, these old radiant heat ceilings are a pain to deal with. I have radiant heat tubing installed in the ceiling plaster.
Click the links to see whats inside dustins toolbox you can do it. In ceiling electric radiant heat and lights heating help. I have radiant heat in my plaster ceiling and over the. Retrofit a drywall radiant wall heating this is how it works. Residents who drive screws carelessly into the ceiling sometimes damage the elements. Electric radiant heating cities inspection service. A quick shot at the ceiling before the heat is turned up and then 15 minutes or so afterwards will tell you if things are warming up. Radiant heating systems are typically located in ceilings and in floors. The most practical thing for homeowner is to use radiant heaters to heat the ceiling mounts. Tools you will need to demo a heated ceiling mattock 2. It is very inexpensive and easy to lower a ceiling to accommodate the radiant ceiling, but difficult to raise a floor. Dayton, i have the utmost respect for all the radiant guys posting here.
The typical install is 38 drywall, heat wires applied with a special t50 staple variant, then 1438 of plaster applied over top. If designed correctly, radiant heat will heat the room to comfort including the air so you have to have enough thermal output if by design, you need 2500 watts to heat an area or room, you install 2500 watts of ceiling heat. I probably put 3 times as many screws in as i would in new drywall. The heated ceiling panels are heated in one of three ways. A warning about radiant barriers aka foil insulation. Cracks basically ran along many of the long seams near the center of the room.
The building was built in 2003 and my unit had concrete ceilings. Most people do not want to continue to use those systems anyway. Our house is heated with electric radiant heat in the ceilings. Radiant ceiling panel systems can be used during a building retrofit process while earning points toward leed certification. The thermostats on radiant ceiling heaters operate differently than with central heating systems. Without air circulation from a forced air system, any soot collects on the colder joist. Click the links to see whats inside dustins toolbox you. Having your ceiling replastered or drywalled after the installation will prevent damages. Jun 19, 2007 if designed correctly, radiant heat will heat the room to comfort including the air so you have to have enough thermal output if by design, you need 2500 watts to heat an area or room, you install 2500 watts of ceiling heat. If its electric, i would either remove it or walk away. What are some common problems with radiant electric.
Electric radiant ceiling heating systems thermaray. Drywall has been the goto finishing material for walls and ceilings for a few decades. What are some common problems with radiant electric ceiling heat. Radiant ceiling heat general drywall discussion drywall talk. I did notice that all of the drywall that has the radiant heat seems very. I have unfortunately radiant electric heat in my ceiling. Ceilings have cracking threw out house and patching with the usual suspects has not worked. Radiant ceilings dont have these problems because people are not usually in contact with the ceiling, so it can be radiating heat for warmth or absorbing it for cooling without problems of. Overheating can also damage plumbing running above your ceiling, which can result in expensive plumbing work.
Radiant heat in ceiling im looking to repair cracks in ceiling with electric radiant heat. Tiny spiderweb cracks may suggest thick application of drywall compound. After cables are installed,2 coats of a plaster product called radex is applied over the cables,then a texture is applied. But i dont have much experience with radiant heat, but i dont think it would be very popular if it usually caused the drywall to crack. Radiant ceiling heat drywall falling again drywall. The home mender shows us how to remove a buckled seam from a ceiling or wall, apply new tape and mud. Jun 17, 2016 radiant ceilings dont have these problems because people are not usually in contact with the ceiling, so it can be radiating heat for warmth or absorbing it for cooling without problems of. Install radiant ceiling panels behind drywall and provide heat without the need for vents or blowers. Before i contact the contractor, id like to know the cause of the cracks. Retrofit drywall radiant ceiling heating this is how it works. Ive also been involved with radiant electric heat for 20 plus years from the ceiling but not radiant hot water. Another thing common to radiant ceiling heat is ghosting of joist and the radiant elements through the drywall or plaster.
I have radiant heat in my plaster ceiling and over the past 23 months of digging, major on going excavation, building destruction and construction four feet from my property line the ceilings have cracked in a number of rooms. Cracks in ceiling with radiant heat coil fine homebuilding. If i had set it to 70 degrees it could swing upwards of 73 and that is hot for us. Here, youll discover ceiling options for your next project. You have to do the whole thing in 3 coat, and do it right, because no drywall product will work. Cracks appear in some of the ceilings along what i presume to be the edges of the underlaying lath boards. The design and construction of your ceiling can make a room. But the outer paper surface requires a drywall primer prior to painting without it, expect trouble. How to fix a ceiling crack, ceiling seam, wall seam. Many posts on here are for ceilings with an attic above. Drywall that sags and cracks may result in breaks in the heating element. Laser thermometers are also a good way to check out radiant heat.
I have radiant ceiling heat in drywall which was installed in 1968. The sagging and cracks indicate there is a good chance the cable is broken anyway. Jun 25, 2019 radiant ceiling panels typically consist of a highdensity fiberglass insulation board, a heating element, and a textured surface coating mounted in a frame. We did not have any ceiling cracks, but skim coating or texturing the ceiling if you avoid screwing anything in should work fine, based on the experiences of others in our complex. It has electric radiant heat in the up stairs ceiling. Radiant ceiling vs radiant floor heating from above. Depending on the heat loss, interior rooms, exterior walls, room size etc, dictated the wire pattern. Again, since most inspectors cannot easily reach an eight foot ceiling, you may have to carry a ladder with you. I live in the chicago area and ive never had the need for a back up heat source. Radiant heat in the ceiling was very popular in my area. I jacked up the kitchen spot and screwed it with a ton of screws and patched it with mud. Some were closer maybe 34 along outside walls, farther apart near the center.
Although plaster can also crack, the prob lem doesnt. The contractor first installed metal tracks into the concrete ceiling and then attached the drywall. Currently they are redoing the kitchen which has a large crack which is about 8 to 10 feet long. Four months have passed and now hairline cracks are appearing between the drywall joints. Im not the original owner and i think at one point the temp was just too high. Thermostat for radiant ceiling heat greenbuildingtalk.
Radiant ceiling heat was real popular here in the 1970s. Do it yourself radiant ceiling heat feb 16 2017, 10. There was about a 1 foot square that was sagging in the kitchen, but the rest of the house looks okay. Our electric radiant ceiling heating system also eliminates cold and hot spots throughout the environment. One of friends recently purchased a house with electric radiant heat in the ceiling. The best way for one to reduce their energy consumption is to use electric radiant ceiling heat. In fact, the temperature variant from ceiling to floor is only about 1 c 2 f. Radiant ceiling heat interior inspections internachi. The radiant heat could also be causing enough expansioncontraction to induce cracking in the drywall. I did notice that all of the drywall that has the radiant heat seems very brittle.
In radiant systems objects of mass are heated without heating the air. I dont know if this is an installation problem or this is common with this heat, but it is a mess. Thinned drywall compound is often used to create a textured ceiling. I have seen in a couple of homes with radiant ceiling heat. Existing homes radiant ceiling panels can be laid into suspended tbar ceilings, suspended on ropes or chains, or mounted on the ceiling surface.
I understand that cracking is not unusual under the circumstances. If it has a sag, certainly it should be looked at because that might mean it is pulling away from its fasteners due to corrosion, inadequate number of fasteners, or leakage if a hydronic heat system. Aug 18, 2017 the home mender shows us how to remove a buckled seam from a ceiling or wall, apply new tape and mud. Find local contractors to repair radiant panel heating units.
Radiant heat, like most electric heating applications, is 100% efficient. Homeadvisor will connect you with prescreened and customerrated contractors in your area. In older construction, radiant ceiling heat often consisted of wires sandwiched between a layer of drywall and a layer of plaster. Modern radiant ceiling heat panels are much more convenient. The thickness of these panels is usually a oneinch panel, ranging in size between 1 x 2 and 4 x 8, powered by 120 or 240volt current. Sshc, inc enerjoy, infrared, radiant heat, yoga heat, heat. Electric radiant heating the ashi reporter inspection.
Get shopping advice from experts, friends and the community. I am having my kitchen remodeled and want to disconnect the radiant ceiling heat, since our house now has two heat pumps. This is because air molecules that come into contact with the radiant ceiling already occupy the highest strata. Broan 1,250watt surfacemount fanforced ceiling heater. Electric radiant heating the ashi reporter inspection news.
How do i repair radiant heating cracks in our ceiling. Although plaster can also crack, the problem doesnt seem to be as pronounced. Can the ceiling panels be repaired some are cracked and sagging as drywall would be. Ceiling radiant heat electrician talk professional. What caused my 4 month old condo drywall ceiling to crack. With an abundance of styles and configurations, a sigma radiant panel selection is sure to meet both the design needs of architects and performance needs of the mechanical engineer. Retrofitting a radiant ceiling heating with drywall panels.
Retrofitting flexiro radint wall heating with plugin drywall system. Finding a manual with the least amount of differential was important along with positive feed back from consumers since king electrics should have worked but failed miserable time and time again. Sometimes, water from an overhead leak can trickle between the ceiling s drywall panels, causing the joint tape to loosen, creating the appearance of a crack, and leaving unsightly yellow or brown. By clicking view pros view matching pros, you affirm you have read and agree to the homeadvisor terms, and you agree and authorize homeadvisor and its affiliates, and their networks of service professionals, to deliver marketing calls or texts using automated technology to the number you provided above regarding your project and other home services offers. If it was applied too thickly, you may notice tiny. Radiant ceilings are perfect for retrofit situations. Radiant heat can dry plaster or ceiling tiles, causing them to crack and peel. Old radiant heat ceiling not cooperating, looking for ways. I am looking for the best solution for fixing these cracks. Old radiant heat ceiling not cooperating, looking for ways to. Radiant ceiling panels offer temperature gradients so low between ceiling and floor that there is less than one degree of difference. In addition, the ceiling mounted infrared panels use less energy than concealed electric or hydronic radiant systems, and are perfect partners for solar, photovoltaic or. Best option to fix cracks in ceiling with radiant heat.